Water treatment converts raw water into water suitable for public supply by removing suspended, colloidal, dissolved and biological impurities. The process involves sedimentation, coagulation, flocculation, filtration, disinfection and aeration, each targeting specific contaminants through different physical and chemical mechanisms.
For GATE Civil Engineering 2027, understanding treatment processes, design parameters, chemical reactions and numerical formulas is essential. GATE Wallah supports preparation through 17 Civil Engineering courses, concept-focused learning, topic-wise, subject-wise, multi-subject and full-length tests, along with performance tracking to help you assess your preparation.
Plain sedimentation removes suspended solids from water. These particles generally have a specific gravity slightly greater than one and settle under gravity. However, excessive flow velocity and turbulence can keep them suspended. A sedimentation tank provides suitable conditions and sufficient time for particles to settle.
The settling process in plain sedimentation is called Type I settling or discrete settling. In this process, particles settle independently without changing their mass, specific gravity, size or shape.
For small particles under laminar conditions, settling velocity is obtained from Stokes’ law:
Settling velocity = g d² (G - 1) / 18 nu
This relationship applies when Reynolds number is less than 1 and particle diameter is generally below 0.1 mm.
The drag coefficient varies with the flow regime:
|
Flow Regime |
Drag Coefficient Relationship |
|
Laminar |
(CD=24/Re) |
|
Transitional |
Depends on Reynolds number and the applicable drag relationship |
|
Turbulent |
Approximately 4, as stated in the lecture |
The Hazen formula is used empirically for particles smaller than 0.1 mm. A modified form applies to particles between 0.1 mm and 1 mm. The Newton formula is used for particles larger than 1 mm, although the laminar-flow relationship is particularly important for GATE questions.
Check:
Basic Thermodynamics: Laws of Thermodynamics GATE
GATE Wastewater Treatment and Sewage Management Notes
1. Surface Overflow Rate
The surface overflow rate is the volume of water flowing through the tank per unit surface area per unit time.
Surface overflow rate = Q / As
It is a tank property and is generally expressed in m/day. Typical values are 10–20 m/day. A particle settles when its settling velocity is greater than the surface overflow rate. If its settling velocity is lower, it escapes with the overflow.
2. Detention Time
Detention time is the average time water remains inside the sedimentation tank.
Detention time = V / Q = L / vf
The usual detention time is 4–8 hours. A detention time below 4 hours may not provide sufficient treatment, while a value above 8 hours is generally not preferred.
3. Flow Velocity
Flow velocity is calculated as:
Flow velocity is:
Flow velocity = Q / Ac
For a rectangular tank, it is Q / (b h). The usual range is 0.15–0.9 m/min.
Where (b) is the tank width and (h) is the water depth.
The usual flow velocity range is 0.15–0.9 m/min.
4. Weir Loading Rate
Weir loading rate is the discharge per unit length of the outlet weir.
Weir loading rate = Q / Lw
It is especially important in circular tanks, where the weir length is the circumference.
The usual detention time is 4–8 hours. A value below 4 hours may not provide sufficient treatment, while a value above 8 hours is generally not preferred.
Strengthen your understanding of sedimentation concepts and practise related GATE numericals with PW GATE Wallah's Civil Engineering courses.
Coagulation removes fine particles that remain suspended after plain sedimentation, particularly colloidal particles. Most colloids carry a negative electrical charge, causing them to repel one another and remain dispersed in water.
A colloidal particle has a positively charged Stern layer and an outer diffuse layer containing both positive and negative ions. The electrical potential at the boundary of the diffuse layer is called zeta potential. A higher zeta potential generally indicates greater colloidal stability and stronger particle repulsion.
The four important coagulation mechanisms are:
Compression of the Electrical Double Layer: Added ions reduce electrical repulsion, allowing van der Waals attraction to bring particles together.
Adsorption and Charge Neutralisation: Positive ions attach to negatively charged colloids and neutralise their surface charge.
Enmeshment in Precipitation: Settling flocs capture colloidal particles within their structure. This process is called sweep coagulation.
Interparticle Bridging: Long-chain polymer molecules connect particles and trap them within a larger structure.
Memory Tip: Remember the four mechanisms as compression, adsorption and charge neutralisation, enmeshment and interparticle bridging.
1. Alum
Alum, or aluminium sulphate, is economical, easy to store and effective within a pH range of 6.5–8.5. It also helps remove colour, odour and unpleasant taste. Alum requires sufficient alkalinity for floc formation.
The alkalinity required is:
Alkalinity required = 300 / 6 × alum dose
Alkalinity deficiency is:
Alkalinity deficiency = required alkalinity - available alkalinity
The lime requirement is:
Lime required = 56 / 100 × alkalinity deficiency
2. Ferrous Sulphate
Ferrous sulfate is effective above pH 8.5. It must be converted into the ferric state to form ferric hydroxide floc. It is cheaper than alum but is more suitable for wastewater.
3. Chlorinated Ferrous Sulphate
Chlorinated ferrous sulphate forms ferric hydroxide and works at pH values below 6.5 or above 8.5.
4. Sodium Aluminate
Sodium aluminate is effective over a wide pH range but is comparatively expensive.
A jar test is performed to determine the optimum coagulant dose. During the test, residual turbidity initially decreases as the coagulant dose increases. It reaches a minimum and may rise again because of charge reversal.
The dose corresponding to the minimum residual turbidity is considered the optimum dose.
Memory Tip: The lowest point on the jar-test curve represents the optimum dose. Further dosing may increase turbidity due to charge reversal.
The treatment sequence consists of three stages:
Coagulation: Rapid and uniform mixing distributes the coagulant throughout the water.
Flocculation: Gentle mixing encourages particle collisions and floc growth.
Sedimentation: The formed flocs settle under gravity.
A combined unit that performs flocculation and sedimentation is called a clariflocculator.
Practise questions on flocculation parameters and settling processes through PW GATE Wallah's topic-wise notes.
Rapid mixing distributes the coagulant uniformly throughout the water. It generally takes 1–3 minutes and uses high turbulence.
The velocity gradient is:
G = Square root of P / (V mu)
Flocculation uses gentle mixing for 20–40 minutes. The velocity gradient should initially be high and then gradually decrease. This produces a floc that is both large and dense.
|
Mixing Condition |
Floc Character |
|---|---|
|
High G and short time |
Small and dense |
|
Low G and long time |
Large but light |
|
Gradually decreasing G |
Large and dense |
After floc formation, particles continue growing while settling. This is flocculent settling, also called Type II settling. Its typical detention time is 2–4 hours, and its surface loading rate is 20–30 m/day.
Filtration removes suspended particles and other impurities that remain after sedimentation and coagulation. Common filter media include silica sand, anthracite coal and garnet.
Important filtration mechanisms include:
Mechanical Straining: Larger particles are retained in the spaces between filter grains.
Sedimentation: Particles settle within the filter media.
Impact: Particles collide with filter grains and become trapped.
Interception: Particles moving with water come into contact with the media and are retained.
Biological Metabolism: Microorganisms help break down organic matter.
Biological layers may include the microorganism layer, known as schmutzdecke, along with autotrophic and heterotrophic layers.
A slow sand filter is a single-media gravity filter that operates at a low filtration rate. Its small grain size, generally around 0.2–0.35 mm, creates small voids and provides a longer contact time. Its reported removal efficiency is approximately 98–99%.
Pretreatment is generally unnecessary, while post-treatment is optional. However, water containing coagulated flocs should not be sent directly to the filter because the remaining flocs may clog the filter bed.
Cleaning and Operation
Cleaning is performed by scraping the upper 1.5–3 cm of sand.
Initial head loss is approximately 10–15 cm.
Cleaning may be required when head loss reaches 70–90 cm.
Cleaning is generally required every 1–3 months.
Memory Tip: A low filtration rate provides a longer contact time and contributes to high removal efficiency.
A rapid sand filter operates at a much higher filtration rate than a slow sand filter. Its shorter contact time generally results in lower removal efficiency.
Coagulation and plain sedimentation are compulsory pretreatment steps before water enters a rapid sand filter.
Unlike slow sand filters, rapid sand filters are cleaned through backwashing rather than surface scraping. Cleaning starts when terminal head loss reaches approximately 3 m or outlet turbidity reaches 2.5 NTU, whichever occurs first.
Backwash velocity must remain lower than the settling velocity of the smallest filter particle.
Memory Tip: Backwash velocity must remain below the settling velocity of the smallest filter particle.
Approximately 2–6% of filtered water may be used for backwashing.
Air Binding: Air becomes trapped in the filter bed, blocking the flow of water and reducing filtration capacity.
Cracking: Cracks develop in the filter bed, allowing water to pass through them instead of moving uniformly through the filter media.
Mud-Ball Formation: Inadequate backwashing allows flocs and impurities to accumulate and form mud balls within the filter bed.
Memory Tip: In a cracked filter bed, water follows the cracks instead of passing uniformly through the filter medium.
A dual-media filter contains coarse anthracite above finer silica sand. This arrangement provides a higher filtration rate, approximately 90% efficiency and longer filter runs.
A multimedia filter may contain additional layers, including garnet, along with anthracite and silica sand.
Disinfection destroys disease-causing microorganisms in water. It also provides protection against later contamination through residual disinfecting power.
Chlorine is widely used because it is effective, economical and provides residual protection.
Important chlorine forms include hypochlorites, chloramines, chlorine gas, and chlorine dioxide. Chloramines are weaker but provide a longer-lasting residual. Chlorine dioxide is effective and avoids trihalomethane formation but is unstable and expensive.
The acceptable free residual chlorine is 0.2 mg/L, while the permissible limit may reach 1 mg/L when alternative sources are unavailable.
Important forms of chlorine used in water treatment include:
Hypochlorites: Compounds that release available chlorine for disinfection.
Chloramines: Weaker disinfectants that provide a longer-lasting residual.
Chlorine Gas: A commonly used form of chlorine for large-scale water treatment.
Chlorine Dioxide: An effective disinfectant that avoids trihalomethane formation but is unstable and expensive.
As stated in the lecture, the acceptable free residual chlorine level is 0.2 mg/L, while the permissible limit may reach 1 mg/L when alternative sources are unavailable.
Breakpoint chlorination involves adding chlorine until the chlorine demand is satisfied and combined chlorine compounds are destroyed. Beyond this point, additional chlorine appears as free residual chlorine.
The process follows these stages:
Chlorine Demand: Added chlorine is consumed by impurities and oxidation reactions.
Combined Residual Formation: Combined chlorine compounds form.
Combined Residual Destruction: Further chlorine addition destroys the combined chlorine compounds.
Breakpoint: The stage at which the combined residual has been largely destroyed.
Free Residual Chlorine: Additional chlorine appears as free residual chlorine.
Memory Tip: Remember the sequence as chlorine demand, combined residual formation, combined residual destruction, breakpoint and free residual chlorine.
The main tests used to determine residual chlorine include:
Orthotolidine test
Starch–iodide test
DPD test
Chlorotex test
Test your understanding of water treatment concepts with PW GATE Wallah's mock tests. Practise GATE-level questions, assess your performance and identify areas that need more revision.
Aeration improves water quality by bringing water into contact with air. It promotes oxygen absorption and the removal of unwanted dissolved gases, particularly carbon dioxide and hydrogen sulphide.
Two main aeration methods are used:
|
Method |
Main Effect |
Examples |
|
Water Into Air |
Greater desorption |
Fountains and spray towers |
|
Air Into Water |
Greater oxygen absorption |
Diffused-air units |
Common aeration units include:
Spray Towers: Break water into small droplets, increasing contact with air and helping remove carbon dioxide and hydrogen sulphide.
Multiple-Tray Aerators: Allow water to pass over several trays, increasing its exposure to air.
Diffused-Air Aerators: Introduce air through diffusers placed below the water surface.
Cascade Aerators: Allow water to flow over a series of steps, increasing air-water contact.
Water treatment is an important topic in GATE Civil Engineering that covers the removal of suspended, colloidal and biological impurities through different treatment stages. Plain sedimentation, coagulation, flocculation, filtration, disinfection and aeration involve distinct mechanisms, design parameters and operating conditions. Understanding their formulas, treatment sequences, and limitations helps you solve both conceptual and numerical questions.
PW GATE Wallah supports GATE 2027 preparation through focused concept learning and different levels of test practice. With 17 Civil Engineering course options, topic-wise, subject-wise, multi-subject and full-length tests, you can practise regularly, assess your performance and identify areas that need further revision.